Heating oil light
Design specification: TU 38.101656-2005
Production method: Heating oil light is produced from diesel fractions of direct distillation and secondary origin - spirits of the thermal and catalytic cracking and coking.
Application: Heating oil light is used for combustion in heating installations of small capacity, located directly in living rooms, as well as in heat the average power used in agriculture for feed preparation, drying grain, fruit, canning and other uses.
| Parameter | Value |
|---|---|
| Composition: 10% distillated at T, °С, not lower than | 160 |
| 90% distillated at T, °С, not higher than | 360 |
| Kinematic Viscosity at 20 °С, mm/s2, max. | 8.00 |
| Pour Point, °С, max. during the period from 1 September to 1 April | minus 5 |
| during the period from 1 April to 1 September | minus 5 |
| Flash Point in Closed Cup, °С, not lower than | 45 |
| Sulfur, wt. %, max. Type IV | 0.5 |
| Type V | 1.1 |
| Hydrogen Sulfide | Absence |
| Copper Plate Testing | Passed Testing |
| Water Soluble Acids and Alkalines | Absence |
| Acidity, mg KOH per 100 cm3 of fuel, max. | 5.00 |
| Ash, %, max. | 0.02 |
| Cokeability of 10% residue, %, max. | 0.35 |
| Water, wt. % | Traces |
| Impurities, wt. % | Absence |
| Color | From colorless to black color |
| Density at 20 °С, kg/m3 | Not standardized. Analysis to be required |
Supply form: Light transparent liquid.
Packaging: Heating oil light is shipped in railway tank-cars and tank-trucks.
Transportation: Heating oil light is transported in railway tank-cars and tank-trucks.
Storage: Stored in metal containers under conditions in accordance with the storage of flammable substances.
Manufacturer: JSC TAIF-NK, JSC TANECO